1 / 5
| Input | Input Voltage Range | 260~485V AC |
| Input Frequency | 45~65Hz | |
| Input Current | <60A | |
| Peak Efficiency | ≥96% | |
| Output | Constant Power Range | 30KW (300~1000V) |
| Output Current Range | 0~100A | |
| Communication Interface | CAN, Max.60 | |
| Product Characteristics | Size (W*D*H) | 300*437*84mm |
| Weight | ≤15kg | |
| Fan Noise | <65dB (1m from the device) | |
| Environmental Condition | Ambient Temperature | -40℃~75℃; The derated function is used when the temperature is above 55℃ |
| Storage Temperature | -40℃~85℃; Humidity: 5%~90% no condensation | |
| Certificate | Certificate | CE, UL |
| Protection Function | Short Circuit Protection | No module output after short-circuit protection, lock after four times automatic restarts |
| Output Overvoltage Protection Point | 1010V±10V (manual recovery, starts locking mode after four times overvoltage) | |
| Overtemperature Protection | Automatic protection starts when detection temperature reaches the preset value; After protection, there is no output. After recovery, you need to start the system by running a command |